Electrician checks

UK electrician calculators, rebuilt around temporary HVAC realities.

Cable size, voltage drop, max demand, Zs/R1+R2, circuit schedules and AI panel tools, but with heaters, dehumidifiers, fans, portable AC and temporary distribution built into the workflow.

Calculator · 110V / site transformer

110V transformer heater check

Check whether a 110V site transformer can realistically power temporary heaters, dehumidifiers, fans or drying kit without overload or unacceptable voltage drop.

For construction sites, drying contractors and hire desks using 110V heaters or 110V drying equipment.

Calculator · PFC / PSCC

PFC / fault current

Estimate PSCC or PEFC from Ze and voltage, compare against device breaking capacity, and draft a quick test-sheet note.

For electricians checking prospective fault current, breaking capacity and temporary distribution assumptions.

Calculator · max Zs / MCB

Max Zs checker

Check a measured Zs value against an entered device limit, with optional 80% rule headroom and clear pass/check wording.

For reviewing Zs results on MCB/RCBO circuits before recording or investigating a circuit.

Calculator · CPC / adiabatic

CPC adiabatic

Use the adiabatic equation shape to compare fault current, disconnection time, k factor and CPC size as a planning aid.

For early CPC adequacy checks where final design still needs current BS 7671 tables and site data.

Calculator · cable correction factor / Iz

Cable correction factors

Stack ambient temperature, grouping, insulation and installation correction factors to see whether corrected Iz still covers load current.

For first-pass cable-capacity checks before final BS 7671 cable selection.

Calculator · RCD / trip time

RCD trip time checker

Review x0.5, x1 and x5 RCD trip-time readings and produce a clear pass/check prompt for the job file.

For checking recorded RCD results before deciding whether to retest, investigate or replace.

Calculator · insulation resistance / IR test

IR test triage

Turn L-N, L-E and N-E insulation-resistance readings into practical next-step notes for damp circuits, appliances and fault finding.

For electricians reviewing low or borderline MΩ readings without treating a web tool as certification.

Calculator · DB schedule / test sheet

DB/test sheet checker

Paste circuit and test-sheet notes to flag missing Zs, R1+R2, IR, RCD or breaker details and generate a cleaner copyable schedule.

For tightening up temporary DB schedules, EICR notes and job-file records before handover.

Calculator · Zs / R1+R2

Zs / R1+R2

Calculate expected Zs from Ze and R1+R2, or derive R1+R2 from measured Zs for circuit assessment notes.

For electricians recording or checking circuit test values.

Calculator · EICR / C1

EICR observation coder

Draft C1/C2/C3/FI-style wording for common observations around overloaded sockets, damaged reels, RCD issues and temporary HVAC equipment.

A wording assistant only. It does not issue certificates or decide compliance for you.

AI tool · AI / plug

AI plug/reel visual check

A photo-led checklist for coiled reels, discolouration, cracked plugs, loose strain relief and overloaded adaptors.

Designed around visible signs only, with clear escalation language.

AI tool · AI / EICR

EICR remedial scope

Turn observations into a clear remedial scope, materials prompt and temporary equipment restriction note.

For drafting, not certification.